Latest revision as of 19:11, 30 May 2012
Inside
Pinout UART
X X TX X GND . X RX X X
X:pin
.:nopin
TX: Transmit (box)
RX: Read (box)
GND: Ground
Connecting to TTL usb cable
To connect to FT232R (6-pole plug):
- Ground to black
- RX on system to TX on cable (orange)
- TX on system to RX on cable (yellow)
Serial configuration is 115200 baud 8N1
Hardware
CS615[bin]$ cat /proc/cpuinfo system type : Sigma Designs TangoX processor : 0 cpu model : MIPS 4KEc V6.9 Initial BogoMIPS : 291.84 wait instruction : yes microsecond timers : yes tlb_entries : 32 extra interrupt vector : yes hardware watchpoint : yes ASEs implemented : mips16 VCED exceptions : not available VCEI exceptions : not available System bus frequency : 198000000 Hz CPU frequency : 297000000 Hz DSP frequency : 297000000 Hz